Analysis of Copolymer Content and Its Distribution in Polyolefin Materials

For some special polyolefin resins, the chemical composition distribution information in soluble matter is very important for R & D personnel to fully understand the performance of polyolefin. The temperature gradient cross chromatography TGIC was born under the condition that the traditional CCD analysis could not meet the requirements. The separation principle of TGIC is realized by using the different crystallization ability of polyolefin and the adsorption and desorption between polyolefin and graphite packing in the column, the unique graphite column also reduces the resin co-crystallization effect.

Analysis of Copolymer Content and Its Distribution in Polyolefin Materials

Classification:

Total Solution

Key words:

Product optimization

Detailed introduction:

For some special polyolefin resins, the chemical composition distribution information in soluble matter is very important for R & D personnel to fully understand the performance of polyolefin. The temperature gradient cross chromatography TGIC was born under the condition that the traditional CCD analysis could not meet the requirements. The separation principle of TGIC is realized by using the different crystallization ability of polyolefin and the adsorption and desorption between polyolefin and graphite packing in the column, the unique graphite column also reduces the resin co-crystallization effect. For example, ethylene and octene copolymerization: traditional CCD analysis cannot understand the information of copolymers with different comonomer contents in rubber phase according to different crystallization ability, while TGIC can realize this requirement according to the adsorption and desorption force of linear polyolefin and graphite surface. The more ethylene content, the greater the adsorption force. Therefore, higher energy is required to leach it from the graphite surface, different ethylene content fractions will be leached out at different temperatures with different adsorption forces. At the same time, TGIC pushes the final leaching temperature of the sample up to about 155 ℃, which can also leave more space for the separation and characterization of the components in the rubber phase, so that the information of the rubber phase components that cannot be obtained by other CCD analysis methods can be obtained.

Figure 1. TGIC analysis of ethylene-octene copolymerization

Related recommendations


Message consultation